Installation, connection and start-up of the boiler Proterm Panther

Hinged gas boiler Proterm Panther 25 KTV with forced discharge of combustion products and model 25 KOV with natural discharge, fueled by natural gas or propane, are designed for heating and hot water supply of country houses, cottages, small garden buildings, communal buildings and other facilities that are equipped with heating system with forced circulation of the coolant and water supply.

Fig. 1. Wall mounted gas boiler 25 KTV PANTHER

1 - closed (sealed) combustion chamber (turbo chamber); 2 - atmospheric burner; 3 - heat exchanger; 4 - circulation pump; 5 - air vent; 6 - heat exchanger of the DHW system; 7 - three-way valve drive; 8 - gas valve; 9 - ignition electrodes; 10 - control electrode; 11 - ignition unit; 12 - control panel; 13 - heating temperature sensor; 14 - emergency temperature sensor; 15 - thrust sensor; 16 - fan; 17 - water pressure sensor

The boiler is designed to operate in the temperature range from +5 to 40 ° C and relative humidity up to 85%.

The temperature of the outer surfaces of the boiler unit (side and top covers) during the operation of the boiler must not exceed the ambient temperature by no more than 50 ° C.

When placing the boiler, it is not allowed to place objects near it:

Made of hardly flammable materials - at a distance of less than 100 mm from the surface;

Flammable materials such as fibreboard, polyurethane, lightweight PVC, synthetic fibers, rubber, etc. - at a distance of less than 200 mm from the surface.

Leave a free space of at least 1m in front of the boiler for maintenance work.

In the Protherm Panther 25 KTV boiler, the exhaust of combustion products and the supply of combustion air are carried out by a special coaxial pipeline or separate pipelines.

Standard parts can be used to create a coaxial flue for almost all installation options. The chimney length, type and number of sections must be agreed with the service organization.

The chimney must be laid so that flue gas condensate can be removed. For this, special sections are intended that are built into the chimney route.

The gas boiler Proterm Panther 25 KOV is designed to remove combustion products into the chimney with natural draft. The connection of the boiler to the chimney is carried out using a pipe with a diameter corresponding to the dimensions of the chimney pipe.

It is not allowed to install objects in the pipe that restrict the passage of combustion products (for example, different kinds heat exchangers, heat recovery, etc.).

Installation of a gas boiler Proterm Panther

The Protherm Panther 25 KTV (KOV) boiler should be installed in closed heating systems with a coolant - water. The nominal pipe diameter of the system is selected based on the pump characteristics. The pipeline is designed according to the required capacity of the given system, not the maximum
boiler heating capacity.

In this case, the flow rate of the coolant must be such that the temperature difference between the supply and return is no more than 20 ° C. The minimum water consumption in the system is 500 l / h. The piping system must be designed in such a way as to ensure the removal of air from it.

Air vents are located at the highest point in the system and on all radiators. The heating system is filled to a pressure of at least 1 bar. The recommended system pressure range is 1.2 - 2 bar.

The expansion tank of the boiler is designed for a heating system capacity of 95 liters. In larger systems, an additional membrane-type expansion vessel should be installed. Heating radiators can be equipped with thermostatic valves.

If the unit is controlled by a room regulator, thermostatic valves are not installed in the room where the room regulator is located. The system must be thoroughly cleaned before installation.

DHW system

The water pressure in the DHW system must be in the range of 1 - 6 bar. If the pressure exceeds 6 bar, a pressure reducing valve must be installed at the inlet. If the hardness of the tap water is high, it is advisable to take appropriate measures to reduce it.

Connecting pipes have external threads. They must not be loaded with the weight of the pipes of the heating system, hot water system or gas supply. The installation dimensions of the connecting pipes (height, distance from the wall and between the individual inlets and outlets) must be strictly observed.

In the lower part of the boiler there is a hydraulic group, which is equipped with a safety-relief valve, a system filling (filling) valve and a drain valve. If the maximum pressure in the system (2.5 kgf / cm2) is exceeded, water may flow out of the safety relief valve or steam may be released.

It is recommended to connect the boiler to the heating system in such a way that during its repair it is possible to drain the water only from the unit. Make-up of the heating system (in small quantities) can be carried out using the make-up valve.

The drain valve is designed to reduce the water pressure in the boiler during possible repairs. It is only possible to partially drain the boiler with this tap. Complete drainage of water or the entire heating system, as well as re-filling, must be carried out using the filling and drain valves (plugs) installed in
certain places in the heating system.

Filling the Protherm Panther boiler and the system with water should be done in the following order:

Check that the pressure in the DHW system is higher than the water pressure in the heating system.

Carefully open the filling valve in the hydraulic group and at the same time monitor the increase in pressure on the boiler pressure gauge. The valve opens by turning counterclockwise, clockwise - it closes.

When the required pressure is reached, the filling valve must be carefully closed and checked whether the water pressure rises (the valve must be completely closed).

If the DHW pressure in the water supply system is the same or lower than the pressure in the heating system, water may leak into the water supply system, which is unacceptable. This can be prevented by installing a non-return valve on the water supply pipe to the boiler.

During repairs, unfavorable building layouts, etc., the boiler can be connected to the heating system, hot water supply system and gas supply with special flexible hoses.

When using flexible hoses, they must have a length of no more than 0.5 m, protected from mechanical stress and damage, exposure to aggressive substances. At the end of the service life of the hoses, they must be replaced with new ones. For connecting the boiler to a pipeline made of copper pipes you can use a special connecting set of shaped copper pipes with fittings.

Tube sizes:

OV inlet and outlet - tube diameter 22 mm.
- DHW inlet and outlet - tube diameter 15 mm.
- Gas connection - tube diameter 22 mm.
- Safety valve connection - pipe diameter 22 mm.

Gas connection

Size 25 KTV (KOV) - ZP is designed to operate on natural gas with a nominal pressure in the distribution network of 1.8 kPa and a calorific value of 35,900 kJ / m3. The diameter of pipes, fittings and gas meter must be selected taking into account other gas appliances of the consumer. The boiler must be supplied with a pipe with a minimum connection diameter of 1/2 ", but preferably with a nominal diameter of 3/4".

Size 25 KTV (KOV) - P is designed for operation on liquefied gas (propane), with a heating value of 12.3 to 13.0 kWh / kg.

Due to the fact that the operation of the boiler using cylinders is problematic, first of all, from the point of view of ensuring a sufficient number of them, as well as their further use, provides for the simultaneous use of a gas tank near the heated facility and its filling by an authorized organization.

Calculations of the required sizes of propane supply from the gas tank to the boiler unit or to other gas appliances are part of the project and delivery of the gas tank. Using the gas pressure reducing valve, it is necessary to ensure the nominal gas pressure upstream of the boiler 3.0 kPa.

Air supply and flue gas discharge

Is the air supply and the removal of combustion products carried out through the coaxial pipeline with an external one? 100 mm. Equivalent pipeline length (numerically equal to the sum running meters straight pipe and the number of elbows 90 °) should be no more than 9 m.When an equivalent pipe length is more than 3 m, the throttle washer must be removed from the fan outlet.

Horizontal sections of the pipeline must be installed with a slope of at least 1.5% towards the flue gas outlet so that condensate flows out of the pipeline. Condensate drainage devices are used in vertical sections.

The pipeline outlet should be located:

At a height of at least 2 m from the foundation of the building in places visited by people and at least 0.4 m - in places not visited by people;

At a distance of at least 0.5 m horizontally from windows, constantly open ventilation grilles and doors;

Above the upper border of windows, bars or doors;

In the area under awnings, balconies and roof edges.

Minimum distance between two adjacent pipe outlets:

Horizontal - 1 m;
- vertically - 2 m.

The direction of the pipe outlet should be oriented so that the combustion products escape into the open space.

The horizontal distance from the end of the pipeline outlet on one facade to the other, with the opposite placement of the outlets, should be:

2 m, if there are no windows or bars on one facade;

1 m, if both facades are without windows or gratings;

4 m, if both facades with windows or gratings (or if there are adjacent exits on the same facade).

In the niche of the facade of the building, the distance between the axis of the pipeline exit and the adjacent plane of the facade should be:

2 m, if the facade has windows or gratings;
- 0.5 m - if they are absent.

All distances are given from the outer border of the window (grating) or door to the pipeline axis. In the space under a canopy (balcony), the pipe head must be at a distance of at least the radius of the circle.

With a vertical outlet of pipelines to the roof, their heads should be located at a distance of at least 0.4 m horizontally and at a height of at least 0.4 m from the roof surface, taking into account its shape.

The chimney outlet should not be located in an explosive space, in the interior of a building or structure, in tunnels or underground passages, in closed spaces.

The hole in the wall for the passage of the coaxial pipeline is made with a certain gap (from 10 to 15 mm). At the end of the installation, the gap is insulated with non-combustible materials (polyurethane foam, gypsum, plaster).

Electrical connection of the gas boiler Proterm Panther

The Proterm Panther boiler must be connected to the mains through a plug socket with a grounding contact, which excludes a zero-phase connection error. The distance from the boiler to the socket must be within the length of the boiler power supply cord (1m).

The boiler must be connected to a protective conductor (earth). The grounding conductor must be accessible for inspection and resistance testing.

It is not allowed to use various tees, extension cords, etc. for the electrical connection. The boiler is protected against overload and short-circuit by fuses P1 –T80 mA / 250V, P2 - T 1.6 A / 250V, installed in the control panel. Before working on the electrical equipment of the boiler, it is necessary to disconnect the boiler from the network by disconnecting the electrical plug from the socket.

To control the boiler from a room regulator, use a regulator with a potential-free output (except for the mains voltage, it is not allowed to supply any other voltage to the boiler). Connect the room regulator to the unit with a flexible two-core cable with a cross-section of 0.5 to 1.5 mm2. Lead the cable out of the boiler through a plastic cable gland.

The terminal block for connecting a room regulator and an external sensor is located below, inside the boiler and is accessible after removing the outer cover and turning the control panel. Before connecting, remove the jumper from the terminal block. Minimum load output contacts of the regulator 24 V / 0.1 A.

The outside temperature sensor must be connected with a two-wire copper conductor, 0.75 mm2. Wiring resistance should be no more than 10 ohms, maximum length - 30 m.

The circuits for connecting the outside temperature sensor and the room regulator must not be routed together with the mains voltage circuits.

Commissioning of the Protherm Panther boiler:

Remove the screw that secures the cover at the bottom of the boiler;

Tilt the cover down (towards you) and lift it off the pins on the top of the camera.

Make sure the gas supply is closed.

Loosen the cap on the automatic air vent located on the pump.

Connect the boiler to the electrical network.

Turn the mains switch to the “I” position. The display will show the code F0 and the pump will run for approximately 1 minute.

Press the Bar / Mode button. The display shows 0.0 (pressure value) and the LED lights up.

The pressure value is displayed for about 25 seconds. The display then returns to its original position. The pressure value can be displayed again by pressing the Bar / Mode button.

Fill the system with water, the pressure should be between 1.2 and 2 bar.

Carefully bleed the air from all heaters (water should flow out continuously, without air bubbles).

Leave the cap on the air separator loose while the boiler is running.

Open the DHW taps to remove air from the DHW circuit;

Make sure that the pressure shown on the display is in the range 1.2 - 2 bar, top up if necessary.

Boiler start-up Proterm Panther

Before starting up the boiler, check:

The main gas supply valve is open,
- the gas valve at the inlet is open,
- closing valves (water, heating) at the outlet are open,
- the unit is connected to the electrical network.

To start the Protherm Panther boiler, do the following:

Switch the mains switch to “I” position;

Set the extract air temperature to 85 ° C and switch off equithermal regulation (E-).

Check the state of the room regulator (it must be closed);

Slowly raise the temperature in the heating system to the maximum (all radiators must be with open valves). The air in the heating water is gradually removed through the automatic air separator. There should be no air at the highest point of the system and in the radiators;

Make up the system up to a pressure of 1.2 bar;

Switch on the boiler again and heat the system to the maximum temperature;

Turn off the boiler, remove air if necessary and recharge the system with water;

Make sure that the pressure gauge shows at least 1.2 bar after cooling the heating system;

If the pressure in the heating system in a heated state is higher by. 0.5 bar than when cold, check the expansion tank setting in relation to the system.

Protective functions of the boiler Proterm Panther

The boiler is equipped with a frost protection function. When the temperature drops below 10 ° C, the pump will automatically turn on. When the temperature drops below 8 ° C, the device will light up and will work until the temperature rises by 25 ° C. In the event of freezing (the extract air temperature is below 3 ° C), the boiler start-up is blocked.

The pump turns on automatically for a short time if it has not been turned on for 24 hours. This provides protection against blocking due to deposits during prolonged shutdown. The pump runs continuously when the temperature rises above 85 ° C (overheating protection).

When the pressure drops, the LED blinks, with a further decrease in pressure, the unit goes out (protection against water loss - alarm F0). When the pressure rises, operation will automatically resume.

The protective functions are only activated when the boiler is connected to the mains voltage (the power cord is in the socket and the mains switch is in the on position (I).

If the boiler has been disconnected from the mains voltage for a long time (a month or more), it is recommended to start it up periodically (at least once a month). The boiler is equipped with a safety valve. When discharging heating water from the valve, turn off the boiler and disconnect it from the mains voltage.

Regulation of the Protherm Panther boiler

When the boiler is operating without a room regulator, it maintains the temperature set on the display.

Adjustment operations:

- select the equithermal regulation mode - select the heating curve and set the E- symbol;

- select the equithermal regulation mode - in the parallel movement option put the symbol P-;

- select the RH temperature mode and adjust it;

- the room regulator must be turned off, a jumper must be installed between the terminals for its connection.

When the Proterm Panther boiler is operating with a room regulator, it maintains the temperature set on the display. In this case, the unit is turned off by the commands of the room thermostat installed inside the control room. This room should not have a thermostatic valve on the radiator.

During installation, the jumper is removed from the boiler terminals and the room thermostat is connected. When operating in equithermal mode, the temperature changes depending on the change in the outside air temperature.

An outside air temperature sensor must be connected to the boiler. The sensor is installed on the coldest wall of a building (north or north-west) at a height of about 2.5 - 3 m. The sensor should not be located in the area of \u200b\u200bventilation emissions from windows or other ventilation devices
and be illuminated by direct sunlight.

Gas inlet pressure control:

Switch off the boiler.

Loosen the screw on the pressure measuring nipple of the gas valve;

Connect an appropriate pressure meter;

Carry out a launch;

Check the inlet gas pressure, if it is below the norm, check the tightness of the gas pipeline;

Switch off the unit and disconnect the pressure gauge, carefully tighten the screw on the measuring point and check the tightness.

if you have vacation home, and communications to it are not summed up, then you can solve the issue expressed in the need for a heating device and provide water heating with the help of boiler equipment. The main thing is to do right choice, because such an installation will occupy a central place in the house and heating system. The choice should be made guided by the rules of safety and reliability.

Modern heating equipment is offered in a huge range. You can choose a floor-standing or wall-mounted model, with or without a chimney, non-volatile or powered by electricity. Modern manufacturers offer for sale single-circuit and double-circuit options for heating equipment. The former will be able to make the house more comfortable and cozy, while the latter will allow you to use hot water. Before making a choice, you need to read the reviews, boilers "Proterm" are not an exception to this rule. They are offered in a wide range of capacities and specifications, you can read about this below.

Review of boilers from the manufacturer "Proterm": "Medved 50 KLZ"

This model of equipment costs 143,914 rubles. It is a gas floor boiler that can run on mains fuel. The consumer will be able to provide a connection to liquefied gas. The equipment is double-circuit and is used for heating, as well as for hot water supply. The design has an open combustion chamber.

A fan must be connected to remove the combustion products. This Proterm Medved boiler has a 10-liter expansion tank. The heat exchanger is based on cast iron, which increases the reliability of operation and the life of the boiler. The manufacturer made sure that the unit is protected from overheating of the coolant in the system. For this, the engineers equipped the model with a cooling circuit. Convenient start-up of the device is ensured by electric ignition.

Considering the model of heating equipment "Bear 50 KLZ", it can be mentioned that it has a capacity of 49 kW. Modulating burner. The maximum power consumption is 50 kW. The gas temperature at minimum and maximum power is 115 ° C.

You may also be interested in how liquefied gas is consumed, the value is 3.8 kg per hour. Heating temperature is equivalent to 85 ° C. At 25 ° C of the heating medium, the productivity reaches 21 liters per minute. If the dimensions of the boiler room are limited, then you should inquire about the design parameters, they are 1385x505x892 mm. The device weighs 210 kg. It belongs to the X4D protection class. The volume of the expansion tank is 10 liters.

The outlet temperature of the coolant can be up to 70 ° C. The possible natural gas pressure is 0.013 bar. The maximum consumption of natural gas is 35.2 m 3 / h. If you plan to connect the equipment on your own, then you may need a chimney diameter, which is 180 mm. At 100% thermal power, the efficiency of the equipment is 92%.

Model reviews

The above-described heating boiler "Proterm", according to consumers, has many positive features, among them it is worth highlighting:

  • simple control;
  • high efficiency;
  • independent regulation of heat loads;
  • the possibility of replacing the middle cast iron sections.

As for the ease of operation, it is provided by an external panel with which you can adjust and monitor the parameters of the floor model. Consumers emphasize that this equipment is used for systems with closed circulation of the coolant.

The device is controlled by a built-in microprocessor. Buyers, in their words, quite often choose this model for the reason that it provides the ability to independently adjust the thermal loads of the hot water supply and heating circuit. The unit is also good because it is resistant to difficult hydraulic conditions.

User's manual

After you familiarize yourself with the characteristics of the Proterm boiler, which you bought or are just planning to purchase, it will not be superfluous to ask what operating rules the manufacturer prescribes. Quite often, this allows you to extend the life of the equipment or exclude its breakdown. As for the above model, it is necessary to install it only in specially equipped rooms.

The device is put into operation only after testing. It is important to follow the safety regulations. They state that the norms for gas supply must be taken into account. You can independently set the temperature of the water in the boiler. This also applies to the heating temperature. The operator will have to press the MODE button.

To set the time intervals for heating water in the boiler, use a timer. The operation of the Proterm gas boiler is also convenient because on the panel you can see equipment messages about errors that occur during operation. For example, if you see the code F1, it will indicate a loss of flame. But the designation F2 indicates that the boiler temperature sensor was defective.

Review of the wall-mounted boiler brand "Cheetah 23 MTV"

Another option for equipment from the manufacturer "Proterm" - "Cheetah 23 MTV". You can buy this model for 42 088 rubles. The device was developed in 2015 and is used for heating as well as hot water supply.

The design provides for a closed combustion chamber, which allows the use of a coaxial chimney. The boiler has a copper primary heat exchanger. The burner is made of chromium-nickel steel. The heat exchanger in the device is plate, it is made of stainless steel.

Specifications

The above described boiler "Proterm Gepard" has a capacity of 24.6 kW. Power consumption reaches 156 watts. Buyers are often interested in the maximum consumption of natural gas, it is 2.9 m 3 / h. The hot water leaving temperature can reach 65 ° C, while its minimum value is 35 ° C. Permissible natural gas pressure 0.02 bar. The volume of the expansion tank is 5 liters.

The equipment belongs to the X4D protection class. The unit weighs 34 kg, this should be taken into account, because the wall-mounted boiler "Proterm" must be securely fixed on a vertical surface. The flue gas temperature is 110 ° C. The maximum fuel consumption when using liquefied gas is 2.1 kg per hour. The heating temperature can reach 83 ° C, while the minimum value is 35 ° C. If you plan to install the device in cramped conditions, then the dimensions of the unit should be especially interesting to you, they are equal to 740x310x410 mm.

Among the main advantages of the above-described equipment option, consumers distinguish:

  • closed combustion chamber;
  • equipping with a coaxial exhaust gas system;
  • the ability to receive information about the operation of the boiler using the liquid crystal display;
  • automatic switching to hot water supply mode when the hot water tap is opened.

If we compare this model with the previous one in the line, then it was equipped with a display by the manufacturer. Its bright backlight allows the user to see the data even in a bright room. The boiler is durable and reliable, which is ensured by a hydraulic block made of composite material. This feature improves the model over the previous generation, where the units were equipped with valve bodies.

User's manual

The boiler manual "Proterm" is supplied in the kit. It is very convenient, because immediately after purchase you can familiarize yourself with it in order to avoid mistakes when using the device. If the boiler is not used for its intended purpose, it may endanger human health and life. If during the operation of the equipment you notice a strong smell of gas, then you should open the doors and windows wide, creating a draft. Do not use open flames or smoke, or switch on plugs, telephones, and other intercoms in the building.

Do not store or use explosive or flammable substances such as paper, gasoline or paint in the same room as the boiler. Adequate air supply must be provided for combustion. Protective devices do not need to be removed or bypassed during operation. It is not recommended to carry out any manipulations with protective systems.

Review of the Panther 35 kW boiler

This gas boiler "Proterm" has an affordable cost, which is 63,398 rubles. The equipment is a two-circuit unit with a closed combustion chamber. The device provides for the presence of a primary heat exchanger and a plate heat exchanger for hot water supply, which is made of stainless steel. The liquid crystal display is located on the external panel, allowing the operator to see the data even in a bright room. The risk of freezing is reduced, as is overheating due to additional safety features.

Model Specifications

After reading the reviews about Proterm boilers, you can understand which model is better to choose. But it is also important to consider the technical characteristics. For example, the "Panther" model has a power of 35 kW. Power consumption reaches 175 watts. The flue gas temperature at minimum output is 102.9 ° C. This traditional boiler provides a maximum power consumption of 38.4 kW.

Electric boiler Proterm A ramp for heating is the most common model in Russia among all manufacturers on the domestic market. Good quality European assembly and reliability of components, many positive reviews for Protherm electric boilers and reasonable prices contributed to their popularity among buyers, both in Russia and abroad.

To understand the advantages and disadvantages of Slovak heating equipment, it is necessary to disassemble the technical characteristics and device of wall-mounted electric boilers Proterm of the Skat series, the model range on the market, and connection features. Let us also consider the problems and malfunctions that may arise during the operation of the device, errors and methods for their elimination.

Model range of electric boilers Proterm Skat, type K (KR)

Today the Slovak company "Protherm" is represented on the Russian market not only with its boilers, but also with eight models of electric boilers of the Skat K (KR) type, differing in power consumption and connection to the electrical network. Country of origin of water heaters - Slovakia.

The company produces only single-circuit devices capable of heating private house total area from 30 to 280 m2. Among them, stand out as single-phase - with the ability to connect to a 220 V power grid, and three-phase - 380 Volts.

Electric boiler Proterm: photo


The main difference between electric boilers of this model range is their rated power, which can be 6 or 9 kW, 12, 14 or 18 kW, 24 and 28 kW. Depending on the model chosen, these are units:

- low power: Skat 6K and 9K;
- medium power: Skat 12K, 14K and 18K;
- high power: Skat 21K, 24K and 28K.

The operation of the electric boiler "Proterm" is controlled by means of special buttons made in the form of multidirectional arrows on the front panel of the heater.

They can set the required water temperature in the heating system, as well as in a remote indirect heating boiler, which is purchased when it is necessary to obtain hot water for household needs... In addition, the button " Mode / Ok»You can turn on (set) the desired operating mode of the electric boiler:

- traditional mode for heating (25-85 ° С);
- "warm floor" mode (30-45 ° С);
- hot water preparation mode in an indirect heating boiler (35-70 ° С).

The multifunctional LCD display informs about the temperature in the heating circuit and the boiler, as well as about problems and errors in the operation of the boiler in case of any malfunctions. Above the display, there are lamps that light up depending on the set operating mode of the device, changes in power consumption and insufficient water pressure in the system.

By default, all electric boilers "Protherm" are 3-phase, however, low-power models 6 and 9 kW ("Skat 6K" and "Skat 9K") can be connected to a single-phase 220 V. Devices of average power, designed for heating houses with an area of \u200b\u200bup to 180 m2, and high-power boilers - more than 20 kW can be installed in private houses or other premises with a total area of \u200b\u200bup to 280-300 m2. We look at the table.

Proterm Skat: cable cross-section, energy consumption


Features of the device of the electric boiler Proterm

The heating device consists of several main elements necessary for its full operation.

1. Copper heat exchanger cylindrical for heating the coolant.
2. Block of heating elements made of copper of different power and quantity with multistage switching.
3. Expansion tank 7 liters to compensate for thermal expansion in the heating system.
4. Hydraulic group consisting of:

- three-speed circulation pump;
- safety valve for 3 Bars;
- automatic air vent.

In addition, an NTS temperature sensor is installed on the heating circuit line, as well as an emergency sensor that protects the unit from overheating. There is a system for protecting the device from freezing. and from blocking the circulation pump.

Electric heating elements are mounted in the heat exchanger of the Proterm boiler, top and bottom. Depending on the model, the number of heating elements may be different. For example, Skat 6K, 9K, 12K and 14K devices have two heating elements, Skat 18K and 21K have three heating elements, 24K and 28K have four. For each model, the heating elements units have different power.

I propose to disassemble in detail internal organization hinged electric boiler "Proterm Skat" according to the instructions:

Internal device "Protherm Skat" according to the instructions


1 - heating block;
2 - air vent valve;
3 - heat exchanger;
4 - pressure sensor;
5 - safety valve;
6 - regulator for setting the circulation pump;
7 - pump status LED;
8 - grounding at the "return";
9 - grounding on the body of the water heater;
10 - pump for circulation;
11 - electrical cable connection;
12 - contactor;
13 - electronic board;
14 - NTS temperature sensor;
15 - emergency temperature limiter sensor.

Electric boiler connection: water circuit, cable

Connecting an electric boiler Protherm


1. Like most modern wall-mounted heating devices, all boiler connections are located at the bottom of the body. This is done to save space in the room where the electric boiler is installed.

2. The heating water circuit is connected using two 3/4 ″ threaded unions. On the left there is a return line (coolant inlet into the boiler), on the right - a straight line (outlet).

3. Nearby: an overflow for a safety valve, a drain valve, as well as connectors for connecting electric cables of different cross-sections. You can monitor the pressure in the heating system by reading the pressure gauge, which is also located in the lower part of the device body.

Electric boilers Proterm Skat: technical characteristics, dimensions

Proterm boilers have a rather compact size of 410 x 740 x 310 mm, which allows them to harmoniously fit into the interior even completely small kitchen or boiler room. We look at the rest of the technical characteristics in the table.

Technical characteristics of electric boilers Proterm


Errors and malfunctions of the electric boiler Proterm: methods of troubleshooting

1. Error code F00, F10, F13, F19.

These codes tell us about a malfunctioning NTS temperature sensor. You may need to replace it or replace the electronic board. But first check that the cable connections are working properly.

2. Error F20.

Defective temperature limit sensor or thermal fuse. Try to short-circuit them one by one. If the boiler shuts down again, replace the faulty element.

3. Error F22.

This error indicates a "dry" start of the electric boiler. Add the water pressure in the system, it should be at least 0.6 bar. The presence of air in pipes and radiators is also possible.

4. Error code F41 and F55. Relay or contactor jammed. Check these parts for defects.

5. Error F63. No communication with EEPROM. Reset to factory settings.

6. Errors F73 and F74.

Errors under these codes indicate problems with the water pressure sensor. You need to check the contacts or replace the sensor itself.

7. Errors F85 and F86. Water freezing in the electric boiler itself (F85) or in the indirect heating boiler (F86).

Wiring diagram for connecting boilers Proterm Skat

Wiring diagram for connecting the boiler Proterm Skat 6, 9, 12, 14K


Advantages of electric boilers Proterm:

- build quality and operational reliability;
- a wide range of different capacities;
modern system security;
- high efficiency of 99.5%;
- the ability to connect additional options and equipment;
good feedback buyers and specialists.

Disadvantages of an electric boiler brand Proterm:

- lack of room equipment in the equipment;
- there are no models with a built-in boiler for heating utility water;
- it is not allowed to use antifreeze liquid as a heat carrier;
- price from 35,000 rubles.

We examined in detail electric boilers Proterm Heating slope, the whole range and technical characteristics. Having disassembled the internal device according to the instruction manual, we revealed the main advantages and disadvantages of these devices. And also focused on possible errors in the event of malfunctions and some ways to fix them with your own hands. Watching the video.

When buying any heating equipment, the user receives instructions. It describes all the points that relate not only to the installation of the unit, but also to its operation. The Proterm Skat 9 kW boiler is no exception. Of course, for some reason, the instruction was lost, then it will not work to start heating the house. After all, an electric boiler needs to be configured correctly. There are certain rules for the installation and operation of an electrical unit. They must be observed. Otherwise, the equipment will not work correctly.

Advantage of the electric boiler Proter Skat

The Proterm Skat unit has a number of advantages. Such heating equipment has become a good alternative to gas heating devices. The popularity of Proterm Skat boilers is increasing every year. After all, such units are ideal for heating houses that are not connected to the main gas pipeline. Electric boilers of this modification are simply irreplaceable for country cottages with periodic or seasonal residence.

Among the advantages of such units are the following:

It is worth noting that electric boilers Proterm Skat during their existence have established themselves as economical and safe heating devices.

Installation features

Boilers Proterm Skat 9 kW are supplied with all the necessary fasteners and elements. Besides the kit includes an instruction, where the process of connecting and setting up the unit is described step by step... It is worth noting that models that differ in power have exactly the same principle of installation, operation, and settings.

Before installing heating equipment Proterm Skat, it is necessary to coordinate all work with electrical distribution services.

Electric boilers Proterm Skat with a power of 9 kW can be connected to the usual 220V power supply... The installation of such heating equipment is carried out using a fastening strip. Such a unit does not have certain restrictions on the choice of the installation site. Of course, there are some requirements - free access is required for service, maintenance, adjustment and repair of heating equipment.

How to install

The electric boiler Proterm Skat is connected to the pipe system using nozzles. The heater is connected in such a way that in the event of a malfunction during operation, the coolant can be drained without hindrance, without affecting the entire system. Additional valves allow you to fill the system with a coolant and drain it. Also, in order to exclude freezing of water in houses with seasonal residence during the cold period, experts recommend removing the coolant completely from the system before the temperatures drop.

The Proterm Skat boiler is connected to the power grid through a power line supplied separately. The mains cable is connected to the terminals located in the lower corner of the housing. Carefully tighten all screws on the connectors. A 9 kW boiler can be connected to a single-phase network.

How to use the boiler Proterm Skat

The process of operating the electric boiler Proterm Skat does not cause any particular difficulties. After all, such heating equipment is equipped with systems for control and regulation... In order for the device to start working, you need to do just a few simple steps:

  1. Connect the unit to the power supply.
  2. On the control panel of the heating equipment select the required temperature regime.
  3. Adjust the unit power.
  4. Carry out a more accurate setting of the temperature regime.
  5. Change the pressure level in the system if necessary.

After the performed manipulations, you must press the "Start" button. That's all the Proterm skat boiler is ready to go. During the first few days of operation, it is worth monitoring the operation of the unit and, if necessary, adjusting the temperature regime. This will reveal some problems in the operation of the unit caused by the presence of air locks in the system.

The gas boiler Protherm (Proterm) is produced by the well-known company Protherm, founded in Slovakia more than a quarter of a century ago. The lineup of this manufacturer is characterized by a good combination the level of heating power and indicators of energy efficiency.

Model range of boilers Protherm - single-circuit and double-circuit

Proterm gas equipment is produced by a European manufacturer in several modifications, which allows you to choose the model that is optimal in terms of functionality, as well as a practical and most convenient model in operation.

Wall type

Wall-mounted gas equipment has undeniable advantages, including compact size, external aesthetics, excellent operational properties, the ability to adapt to operation with different energy carriers by means of a standard nozzle replacement, as well as cost effectiveness.

  • "Panther". Inexpensive model with two heat exchangers and water heating. A modern heater with the ability to function in a closed system. Possesses reliable protection from freezing, automatic shutdown of gas supply and control of pump operation.

Inexpensive heater option in the Protherm line

  • "Jaguar". A budget option equipment that does not have a winter / summer mode. A two-circuit unit with a closed combustion chamber and control by means of handles.

Simple model with the minimum required set of functions

  • "Cheetah". Double-circuit turbocharged boiler with a capacity of 11-23 kW and a closed combustion chamber. Even low-power models are capable of heating 10-11 liters of water in one minute. A wall-mounted device in which the movement of the heat carrier is forced.

Turbocharged boiler with high efficiency

  • "Tiger". Differs in neat appearance, informative LCD display and very simple operation. There is a possibility of programming for different modes of operation or functioning in the automatic mode "comfort". There is the possibility of automatic regulation of the combustion process, it is distinguished by a special ignition system.

Compact equipment with different operating modes

Main characteristics of the boiler

Floor type

Floor-standing single-circuit and double-circuit boilers have several advantages that make this type of equipment in demand among consumers. High performance indicators, maximum thermal efficiency, economical fuel consumption, wide functionality and guaranteed durability cannot be ignored.

  • "Bear". The high quality cast iron heat exchanger makes the unit durable and very reliable. The model has a "Winter-Summer" mode and convenient traction control. It has automatic regulation of the combustion process and has a special ignition system.

A cast iron heat exchanger assumes a long-term boiler operation

  • "Buffalo". An easy-to-use and durable boiler with high efficiency, capable of operating on various types of fuel. A very powerful unit with a high degree of reliability.

Powerful equipment that can run on different types of fuel

The main characteristics of the Bizon model

Floor standing boiler with reliable heat exchanger

Main characteristics of the model

Stationary heating gas boiler

Main characteristics of the model Bear KLOM17

Gas boiler device Proterm

Various modifications have individual characteristics of the device.

The manufacture of boilers using low-temperature cast iron contributes to the effective minimization of heat losses. The peculiarity of the device of the "Proterm" brand heating devices is also an unusual, rather environmentally friendly way of burning fuel.

The main units of gas heating equipment are:

  • ignition system;
  • burner;
  • heat exchanger.

The heat source is represented by the flame of the burner, in which the gas is burned, and the heat exchanger is responsible for heating the heat carrier. The gas supply process is controlled by a thermostat, while the combustion products, represented mainly by water vapor and carbon dioxide, are removed through the chimney system.

Proterm boilers are used for heating and hot water supply

How to connect and configure

Basic conditions for the installation of gas heating equipment from the manufacturer "Proterm":

  • installation of the boiler and the necessary auxiliary equipment is carried out in accordance with the design documentation, taking into account the requirements of SNiP and the manufacturer's recommendations;
  • installation of equipment is carried out in a room specially designed for this purpose, and with a special modification of the unit - exclusively in well-ventilated annexes;
  • the process of installation and commissioning is carried out by specialists who have completed the training course for the installation and maintenance of gas equipment;
  • elimination of any boiler malfunctions is performed by a service organization authorized by the manufacturer of heating and hot water equipment;
  • independent installation work will void the consumer's warranty for the unit and its repair;
  • when unpacking the heating equipment, the completeness of the supplied boiler and the compliance with the type of fuel used must be checked.

Before proceeding with the installation, you need to carefully read the attached instructions, and during the installation process, all the recommendations given in the accompanying documents must be observed. Equipment markings must not be damaged or removed.

Standard technology for connecting and setting up a gas boiler:

  • fixing the unit to the wall is carried out using screws with appropriate gaskets;
  • nozzles for connection should not be loaded with a pipe heating system, a hot water system or gas supply elements;
  • the installation dimension of the connection of the pipes, including their height and the required distance from inlet to outlet, must be strictly observed;
  • the placement of the hydraulic group is carried out on the lower part of the gas equipment, and the system is necessarily equipped with a filling valve and safety relief valves;
  • in conditions of exceeding the maximum pressure indicators inside the system, steam or water is discharged from the safety-relief valves;
  • connecting the unit to the heating system presupposes the possibility of performing the full scope of preventive maintenance and repair work;
  • water is delivered to the heating system by means of a filling valve, and a drain device is used to lower the pressure or partially drain the heat carrier;
  • full-fledged drainage and filling functions are possessed by special exits installed on dedicated sections of the heating system;
  • the pressure of the hot water supply at the supply to the equipment must exceed those in the heating system;
  • in the position of the valve "Filling" (hydraulic group), it is imperative to check the operation of the system by means of a boiler pressure gauge;
  • valves are opened counterclockwise and closed strictly clockwise.

The items of boiler equipment maintenance under warranty do not include measures presented by de-airing and adjusting the expansion tank.

Video: Connecting the boiler Proterm

Video: Configuring Protherm Equipment

Brief operating instructions

Competent setting of gas boilers Protherm provides optimal temperature conditions in rooms of different purpose and area. Among other things, the regulation of the automation of such equipment contributes to an increase in the efficiency of the unit, and also makes its operation reliable and safe. Modern automation solves problems:

  • opening and closing fittings in the gas supply system;
  • the process of starting the unit in automatic mode;
  • installed or emergency shutdown of boiler equipment;
  • regulation of the flame level in the burner by means of a temperature sensor;
  • display on the screen of air temperature indicators, heating agent heating level and other parameters.

Instructions for setting up a gas boiler:

  • connecting the thermostat to a temperature sensor fixed in the room, and setting the required values \u200b\u200ballow you to obtain a comfortable temperature regime for heating;
  • the installation of a thermostatic valve on the supply pipes in front of the heating radiators helps to change the cross-sectional area and easily carry out the process of regulating the temperature of the heat carrier;
  • the first start-up of the system at the limiting temperature allows the used coolant to freely enter the reservoir, which contributes to its maximum filling;
  • improving efficiency is facilitated by timely removal of scale and soot, as well as control of the lack of air in the system and installation of a draft limiter;
  • regulation of pressure indicators is carried out using special valve regulators, and in order to increase the pressure, a circulation pump is installed;
  • the reduction of the boiler burner power is carried out automatically through the service menu, and the power regulation for increase is carried out by installing additional radiators or replacing the existing ones with the most powerful models;
  • many units are characterized by full performance at a pressure of 1.5 atm., and normally this value is 0.3 atm. lower than the indicators in the heating system;
  • a slight decrease in the pressure level in the unit is restored during a standard restart;
  • automatic selection of the operating mode of the gas boiler helps maintain the desired temperature level even with a long absence of consumers in the room.

The process of switching on the boiler for the first time is accompanied by its short and energetic operation after the unit is fully connected to the heating system, due to which it is easy to check the correct installation of the boiler equipment and the full functioning of the heating.

Common errors and malfunctions

Some of the most common malfunctions of Proterm gas boilers can be completely eliminated by yourself, but the correction of the most difficult errors must be entrusted to the professionals of the service center.

Error / malfunction Code / designation Remedies
Reduced pressure level in the unit or heating system F0 Check the function of the pressure sensor, make sure there is no cable damage and the integrity of the boiler control board
No flame in the burner F1 Check the functionality of the emergency thermostat and the ignition transformer, make sure the gas supply and the integrity of the gas valve, restart
Rapid overheating of the gas boiler F3 Eliminate clogging in the water filter and pump, check the performance of the heat exchanger, replace the anti-freeze mixture
Open in temperature sensor circuit F4 Check the resistance readings on the sensor, make sure that the cables connecting the control panel and the sensor are intact
Input signals are not recognized F7 Make sure that the information panel is working, check the panel connectors
Opening the NTC sensor circuit and grounding the DHW boiler F8 Ring the connections, disconnect and reconnect the elements or completely replace the sensor
Short circuit on the traction sensor F15 Disassemble and clean the terminal connections, clean the tubes, if necessary, make full replacement node
Low pressure level inside the heating circuit F22 Top up the heat carrier to the required level, make sure that the system is completely sealed and there is no leak
Rapid rise in coolant temperature F24 Replace insufficiently productive pump equipment and get rid of the air in the system.
Unsuccessful initial ignition F28 To eliminate the error / malfunction, it is necessary to involve the specialists of the service center
Fan anti-freeze protection activation F33
Repeated sensor error for pressure F75

Modern heating equipment from a manufacturer from Slovakia, which category includes single and double-circuit gas boilers Protherm, differs high reliability and model variety. These solid and inexpensive boilers of European quality from the "middle class" are deservedly popular and are invariably in demand by domestic consumers.